Follow Discord
Sweep 10 Nov 2026 · 02:18Z Build v2.1.322 539 read Stable v2.1.311 Latest v2.1.322 Next v2.1.322 Feeds RSS JSON llms.txt llms-full.txt Unofficial
One change · claude-code

Continue local sessions from any device with Remote Control changedremote-control

Nearest release: v2.1.322, published 17 hours before upstream edited the page. Shown because the two are within 24 hours of each other. Nothing here says the release caused the edit.

Upstream edited this page at 10 Nov 2026 19:50 UTC, give or take a minute or two: the time comes from Anthropic’s own sitemap rather than from a commit. This site recorded the change at 10 Nov 2026 20:07 UTC.

Upstream edited
Recorded here
Lines+4added
Lines−4removed
From line 29 where the diff opens
First seen 14 Aug 2026 this site's first read of the page
Recorded edits77to this page, all time

The whole hunk

from line 29, old and new numbered
/
lines
from line 29
2929 * You point [`ANTHROPIC_BASE_URL`](https://code.claude.com/docs/en/env-vars) at a host other than `api.anthropic.com`, such as an [LLM gateway](https://code.claude.com/docs/en/llm-gateway) or proxy. Unset the variable to use Remote Control.
3030 * You sign in through an enterprise [Claude apps gateway](https://code.claude.com/docs/en/claude-apps-gateway).
3131* **Feature-flag evaluation**: if you set an [environment variable that turns off feature-flag evaluation](https://code.claude.com/docs/en/env-vars.md#features-that-need-feature-flag-fetching), whether Remote Control is available depends on which one:
32 * If you set `CLAUDE_CODE_DISABLE_NONESSENTIAL_TRAFFIC` or `DISABLE_GROWTHBOOK`, Remote Control is unavailable. Unset the variable wherever it's set, in your shell environment or in the `env` block of a [`settings.json` file](https://code.claude.com/docs/en/settings-reference#all-settings), to use Remote Control.
32 * If you set `CLAUDE_CODE_DISABLE_NONESSENTIAL_TRAFFIC` or [`CLAUDE_CODE_DISABLE_FEATURE_FLAGS`](https://code.claude.com/docs/en/env-vars#variables), Remote Control is unavailable. Unset the variable wherever it's set, in your shell environment or in the `env` block of a [`settings.json` file](https://code.claude.com/docs/en/settings-reference#all-settings), to use Remote Control.
3333 * If you set only `DISABLE_TELEMETRY` or `DO_NOT_TRACK`, Remote Control stays available unless your organization requires [Trusted Devices](#trusted-devices). If it does, unset the variable to use Remote Control. Using Remote Control with either variable set requires Claude Code v2.1.283 or later, or v2.1.304 or later in the Claude Desktop app.
3434* **Workspace trust**: in a directory you haven't trusted yet, `claude remote-control` prints what trusting it turns on and asks `Trust <directory>? [y/N]` before it starts. Answering `y` saves the choice, except in your home directory, where trust is never saved and the question returns on every run. When its standard input or output isn't a terminal, the command can't ask and exits with a [`Workspace not trusted`](https://code.claude.com/docs/en/errors#workspace-not-trusted-when-starting-remote-control) error.
3535 
from line 213
213213 
214214#### Auto-connect with `DISABLE_TELEMETRY` or `DO_NOT_TRACK` set
215215 
216With only `DISABLE_TELEMETRY` or `DO_NOT_TRACK` set, your sessions don't auto-connect through your organization's admin default or Claude Code's own default. If something else makes Remote Control unavailable for you, such as `DISABLE_GROWTHBOOK` or an LLM gateway, start with [Requirements](#requirements) instead.
216With only `DISABLE_TELEMETRY` or `DO_NOT_TRACK` set, your sessions don't auto-connect through your organization's admin default or Claude Code's own default. If something else makes Remote Control unavailable for you, such as [`CLAUDE_CODE_DISABLE_FEATURE_FLAGS`](https://code.claude.com/docs/en/env-vars#variables) or an LLM gateway, start with [Requirements](#requirements) instead.
217217 
218218Before you turn auto-connect on with only `DISABLE_TELEMETRY` or `DO_NOT_TRACK` set, confirm that your Claude Code version meets the [requirement for these variables](#requirements). Then check whether your organization requires [Trusted Devices](#trusted-devices):
219219 
from line 454
454454 
455455An [environment variable](https://code.claude.com/docs/en/env-vars.md#features-that-need-feature-flag-fetching) that turns off feature-flag evaluation is set, and the full message names the variable Claude Code found. On versions before 2.1.154, the same configuration produces "Remote Control is not yet enabled for your account" instead. What to do depends on the variable the message names:
456456 
457* **`CLAUDE_CODE_DISABLE_NONESSENTIAL_TRAFFIC` or `DISABLE_GROWTHBOOK`**: unset the variable wherever it's set, in your shell environment or in the `env` block of a [`settings.json` file](https://code.claude.com/docs/en/settings-reference#all-settings).
458* **`DISABLE_TELEMETRY` or `DO_NOT_TRACK`**: on a Pro, Max, Ultra, Team, or Enterprise plan with `DISABLE_GROWTHBOOK` unset, Remote Control stays available with these variables set, unless your organization requires [Trusted Devices](#trusted-devices). If it does, unset the variable wherever it's set to use Remote Control. On v2.1.154 through v2.1.282, you see this message with either variable set, so update Claude Code to a version that meets the [requirement for these variables](#requirements).
457* **`CLAUDE_CODE_DISABLE_NONESSENTIAL_TRAFFIC`, `CLAUDE_CODE_DISABLE_FEATURE_FLAGS`, or `DISABLE_GROWTHBOOK`**: unset the variable wherever it's set, in your shell environment or in the `env` block of a [`settings.json` file](https://code.claude.com/docs/en/settings-reference#all-settings).
458* **`DISABLE_TELEMETRY` or `DO_NOT_TRACK`**: on a Pro, Max, Ultra, Team, or Enterprise plan with `CLAUDE_CODE_DISABLE_FEATURE_FLAGS` and `DISABLE_GROWTHBOOK` unset, Remote Control stays available with these variables set, unless your organization requires [Trusted Devices](#trusted-devices). If it does, unset the variable wherever it's set to use Remote Control. On v2.1.154 through v2.1.282, you see this message with either variable set, so update Claude Code to a version that meets the [requirement for these variables](#requirements).
459459 
460460### "Remote Control is only available when using Claude via api.anthropic.com"
461461 
Feedback