Recorded edits31to this page, all time

### Audit local connector tool calls

The whole hunk

from line 350, old and new numbered
/
lines
from line 350
350350| `read_resource` | Fetch a specific item, such as a message, event, or file |
351351| `teams_list_chats` | List the user's Teams chats and their members, to find a chat to read or post in |
352352| `get_me` | Return the signed-in user's own profile |
353| `get_granted_scopes` | List the scopes that Microsoft Entra grants the connector for the signed-in user |
353354| `search_people` | Search for people by name or email address (needs `People.Read`) |
354355| `teams_list_teams`, `teams_list_channels` | List the user's teams and a team's channels (need `Team.ReadBasic.All` and `Channel.ReadBasic.All`) |
355356| `teams_list_channel_messages` | List a channel's messages, or the replies in one conversation (needs `ChannelMessage.Read.All`) |
from line 493
492493The connector's Entra tokens are stored on the device, encrypted by Claude Desktop using the operating system's secure storage. Each configured entry has its own token store, and tokens persist across app restarts so users are not asked to sign in again each session.
493494 
494495Selecting **Disconnect** next to the connector signs the user out and deletes its stored tokens. Where the user signed in through the broker, the device's work or school account itself is managed by the operating system and remains after Disconnect; remove the account in Windows Settings (**Accounts → Access work or school**) or macOS Company Portal, or revoke the user's sessions in Entra, to end access entirely. With `continuousAccessEvaluation` at its default of `enabled` on Claude Desktop 1.49585.0 or later, Microsoft Graph rejects the connector's current access token within minutes of the revocation. With `continuousAccessEvaluation` set to `disabled`, or on earlier app versions, revocation takes effect once the current one-hour access token expires.
496 
497### Audit local connector tool calls
498 
499Claude Desktop records each approved tool call to the local Microsoft 365 connector as a `builtin_m365_call` event, and sends it to your [OTLP collector](https://claude.com/docs/third-party/claude-desktop/telemetry.md#sending-telemetry-to-your-own-collector) under the `service.name` value `claude-desktop`. To receive the event, set [`otlpDesktopLogLevel`](https://claude.com/docs/third-party/claude-desktop/configuration#otlpdesktoploglevel) to `info` or `debug` (the default is `error`), then in your collector keep the log records whose body is `builtin_m365_call`. Each record identifies the user as described under [User attribution](https://claude.com/docs/third-party/claude-desktop/telemetry.md#user-attribution).
500 
501Whatever [`otlpContentCapture`](https://claude.com/docs/third-party/claude-desktop/telemetry#content-capture) is set to, the event carries the tool's name but not its arguments or the text of its result. Its attributes include:
502 
503* **`m365_tool`**: the tool's name, such as `outlook_email_search`
504* **`status`**: `ok`, `error`, or `cancelled`, or, when no tool ran, `user_disconnected` (the user isn't signed in to the connector) or `respawn_failed` (the app couldn't start or reach the connector)
505* **`is_write`**: `false` when the app confirms that the tool only reads, otherwise `true`
506 
507Because `true` doesn't prove a write, compare `m365_tool` with the read and search tools listed under [Configure scopes](#configure-scopes), and count every other tool as a write.
508 
509A call that the user declines produces no `builtin_m365_call` event. It appears in the session's telemetry as a [`tool_decision`](https://claude.com/docs/cowork/monitoring#tool-decision-event) event with `decision` set to `reject`.
495510 
496511### Troubleshoot the local connector
497512 
Feedback