Follow Discord
Sweep 20 Nov 2026 · 19:55Z Build v2.1.330 547 read Stable v2.1.323 Latest v2.1.330 Next v2.1.330 Feeds RSS JSON llms.txt llms-full.txt Unofficial
One change · api

whats-new-opus-5-5 changedmodels/opus-5-5/whats-new-opus-5-5

Nearest release: v2.1.323, published 4 hours after this site recorded the change. Shown because the two are within 24 hours of each other. Nothing here says the release caused the edit.

Recorded here
Lines+9added
Lines−5removed
From line 62 where the diff opens
First seen 23 Sep 2026 this site's first read of the page
Recorded edits23to this page, all time

The whole hunk

from line 62, old and new numbered
/
lines
from line 62
6262| From Claude Opus 5.5, to Claude Fable 5.1 or Claude Mythos 5.1 | Yes, on the Claude API only |
6363| From Claude Opus 5.5, to any other model | No |
6464 
65When a request carries a block the target model can’t read, the API drops it before the model sees it. The request succeeds, and dropped blocks aren’t billed. With the `thinking-binding-controls-2026-08-01` beta header, the drop is reported in a top-level `input_transformations` array. See [Switching models mid-conversation](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#switching-models). For switches that don’t involve Claude Opus 5.5, see [Which model switches keep the reasoning on the Claude API](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#which-model-switches-keep-reasoning).
65When a request carries a block the target model can’t read, the API drops it before the model receives it. The request succeeds, and dropped blocks aren’t billed. With the `thinking-binding-controls-2026-08-01` beta header, the API reports the drop in a top-level `input_transformations` array. See [Switch models and back](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#switching-models). For switches that don’t involve Claude Opus 5.5, see [Which model switches keep the reasoning on the Claude API](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#which-model-switches-keep-reasoning).
6666 
67The API also checks whether anything before a Claude Opus 5.5 thinking block (the `system` prompt, the `tools`, or an earlier message) has changed since the block was produced. Keep the conversation append-only: change instructions or tools with [mid-conversation system messages](https://platform.claude.com/docs/en/build-with-claude/mid-conversation-system-messages) rather than edits.
67The API also checks whether anything before a Claude Opus 5.5 thinking block has changed since the model produced the block. This prefix check covers the `system` prompt, the `tools`, and every earlier message. Keep the conversation append-only: change instructions or tools with [mid-conversation system messages](https://platform.claude.com/docs/en/build-with-claude/mid-conversation-system-messages) rather than edits.
6868 
69A request that replays a block after such a change, with `thinking.block_binding.prefix_mismatch_behavior` unset, gets a 400 error. This applies to accounts created on or after August 31, 2026, 00:00 UTC. [Preserved thinking availability](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#feature-availability) lists the platforms where this applies. On accounts created before that date, the request might or might not get the error. To drop the affected blocks instead, send the `thinking-binding-controls-2026-08-01` beta header and set the field to `"drop_block"`. See [Preserved thinking](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking) and the migration guide’s [note on thinking blocks](https://platform.claude.com/docs/en/models/opus-5-5/migration-guide#thinking-blocks).
69Failing the [prefix check](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking/prefix-checks#prefix-check) might or might not result in a [400 error](https://platform.claude.com/docs/en/api/errors#thinking-block-conversation-mismatch). To identify and handle both cases, see [Prefix checks on thinking blocks](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking/prefix-checks).
7070 
71The prefix check runs on the Claude API and on [some cloud platforms](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#feature-availability).
72 
73See [Preserved thinking](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking) and the migration guide’s [note on thinking blocks](https://platform.claude.com/docs/en/models/opus-5-5/migration-guide#thinking-blocks).
74 
7175### Some computer use tool versions are not supported
7276 
7377Claude Opus 5.5 supports [computer use](https://platform.claude.com/docs/en/agents-and-tools/tool-use/computer-use-tool) through the `computer_toolset_20260801` toolset. On Amazon Bedrock, Claude Opus 5.5 also accepts the `computer_20251124` tool with the `computer-use-2025-11-24` beta header. Claude Opus 5.5 returns a 400 error for any computer use tool version it doesn’t accept, such as `computer_20251124` on the Claude API. The Claude API’s `invalid_request_error` message names the rejected type and, after `Did you mean one of`, lists the tool types the model accepts. The message begins:
from line 84
8084 
8185## Feature support
8286 
83Claude Opus 5.5 supports [per-message effort](https://platform.claude.com/docs/en/build-with-claude/effort-per-message) (in beta), [mid-conversation system messages](https://platform.claude.com/docs/en/build-with-claude/mid-conversation-system-messages), [task budgets](https://platform.claude.com/docs/en/build-with-claude/task-budgets), [prompt caching](https://platform.claude.com/docs/en/build-with-claude/prompt-caching) with a 512-token minimum cacheable prompt, [batch processing](https://platform.claude.com/docs/en/build-with-claude/batch-processing), the [Files API](https://platform.claude.com/docs/en/build-with-claude/files), [PDF support](https://platform.claude.com/docs/en/build-with-claude/pdf-support), [vision](https://platform.claude.com/docs/en/build-with-claude/vision), and server-side and client-side tools (see [Tool use with Claude](https://platform.claude.com/docs/en/agents-and-tools/tool-use/overview)). See each feature’s page for model availability.
87Claude Opus 5.5 supports [per-message effort](https://platform.claude.com/docs/en/build-with-claude/effort-per-message), [mid-conversation system messages](https://platform.claude.com/docs/en/build-with-claude/mid-conversation-system-messages), [task budgets](https://platform.claude.com/docs/en/build-with-claude/task-budgets), [prompt caching](https://platform.claude.com/docs/en/build-with-claude/prompt-caching) with a 512-token minimum cacheable prompt, [batch processing](https://platform.claude.com/docs/en/build-with-claude/batch-processing), the [Files API](https://platform.claude.com/docs/en/build-with-claude/files), [PDF support](https://platform.claude.com/docs/en/build-with-claude/pdf-support), [vision](https://platform.claude.com/docs/en/build-with-claude/vision), and server-side and client-side tools (see [Tool use with Claude](https://platform.claude.com/docs/en/agents-and-tools/tool-use/overview)). Task budgets and per-message effort are in beta. See each feature’s page for model availability.
8488 
8589### Fast mode
8690 
from line 104
100104 
101105* **The default effort is `medium`.** A request that omits `effort` runs at `medium`; on Claude Opus 5 it ran at `high`. Set `effort` explicitly and re-run your sweep; see [Calibrate effort](https://platform.claude.com/docs/en/build-with-claude/prompt-engineering/prompting-claude-opus-5-5#calibrate-effort).
102106* **More thinking per turn at a given effort level.** At the same [effort](https://platform.claude.com/docs/en/build-with-claude/effort) setting the model tends to think more per turn than Claude Opus 5, most of all at `xhigh` and `max`. Re-run your effort sweep rather than carrying a setting over, and leave room in `max_tokens` for the thinking. See [Calibrate effort](https://platform.claude.com/docs/en/build-with-claude/prompt-engineering/prompting-claude-opus-5-5#calibrate-effort).
103* **Text between tool calls comes back in thinking blocks.** The short notes the model writes between tool calls arrive as [progress-update `thinking` blocks](https://platform.claude.com/docs/en/build-with-claude/thinking#progress-updates) rather than `text` blocks, so at the default `display: "omitted"` an application that streams them to its users goes quiet between tool calls, with no error. The migration guide explains [how to receive text between tool calls](https://platform.claude.com/docs/en/models/opus-5-5/migration-guide#text-between-tool-calls), and [User-facing progress updates](https://platform.claude.com/docs/en/build-with-claude/prompt-engineering/prompting-claude-opus-5-5#user-facing-progress-updates) covers how to ask for more of them.
107* **Text between tool calls comes back in thinking blocks.** The short notes the model writes between tool calls arrive as [progress-update `thinking` blocks](https://platform.claude.com/docs/en/build-with-claude/thinking#progress-updates) rather than `text` blocks. At the default `display: "omitted"`, an application that streams them to its users goes quiet between tool calls, with no error. The migration guide explains [how to receive text between tool calls](https://platform.claude.com/docs/en/models/opus-5-5/migration-guide#text-between-tool-calls). For how to ask for more of them, see [User-facing progress updates](https://platform.claude.com/docs/en/build-with-claude/prompt-engineering/prompting-claude-opus-5-5#user-facing-progress-updates).
104108* **More safeguard categories.** The model runs a biology safety classifier in addition to the cybersecurity one. As on Claude Opus 5, requests that push it to reproduce its internal reasoning in the response text might be declined with the `reasoning_extraction` category. See [Refusals and fallback in Claude Opus 5.5](https://platform.claude.com/docs/en/models/opus-5-5/whats-new-opus-5-5#refusals-and-fallback) and [Safeguard refusals](https://platform.claude.com/docs/en/build-with-claude/prompt-engineering/prompting-claude-opus-5-5#safeguard-refusals).
105109* **Sharper reading of charts, diagrams, and screenshots.** The model reads values off dense charts and layout-dependent visuals much more precisely without tools, so prompt-side vision workarounds built for earlier models might no longer be needed; image tools still add accuracy on the densest inputs. See [Tools for complex visual inputs](https://platform.claude.com/docs/en/build-with-claude/prompt-engineering/prompting-claude-opus-5-5#tools-for-complex-visual-inputs).
106110 
Feedback