Follow Discord
Sweep 20 Nov 2026 · 19:55Z Build v2.1.330 547 read Stable v2.1.323 Latest v2.1.330 Next v2.1.330 Feeds RSS JSON llms.txt llms-full.txt Unofficial
One change · claude-docs

Deploy Claude Desktop on 3P with an LLM gateway changedthird-party/claude-desktop/gateway

Nearest release: v2.1.327, published an hour after upstream edited the page. Shown because the two are within 24 hours of each other. Nothing here says the release caused the edit.

Upstream edited this page at 17 Nov 2026 19:30 UTC, give or take a minute or two: the time comes from Anthropic’s own sitemap rather than from a commit. This site recorded the change at 17 Nov 2026 19:37 UTC.

Upstream edited
Recorded here
Lines+11added
Lines−0removed
From line 523 where the diff opens
First seen 14 Aug 2026 this site's first read of the page
Recorded edits63to this page, all time

### Gateway requirements for preserved thinking

The whole hunk

from line 523, old and new numbered
/
lines
from line 523
523523 
524524On a response that delivers only keep-alive pings, a session accepts about five minutes of pings and then waits [`inferenceStreamIdleTimeoutSec`](https://claude.com/docs/third-party/claude-desktop/configuration#inferencestreamidletimeoutsec) seconds more for model output (300 by default, so about ten minutes in all). Raise that key if your provider needs longer than that before its first output on a large request.
525525 
526### Gateway requirements for preserved thinking
527 
528On models with [preserved thinking](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking), the provider ties each thinking block that Claude produces to the `system`, `tools`, and `messages` content that came before it. A session sends the thinking blocks from earlier turns back in later requests. That content can change after Claude produces a block, for example in your gateway or after a Claude Desktop update. If it has changed, the provider can reject the request with a `400` whose message says that the block is `bound to a different conversation`.
529 
530On these models, your gateway needs to do the following:
531 
532* **Forward the request content unchanged**: send `system`, `tools`, and `messages` to the provider as the session sent them, including the [attribution block](https://code.claude.com/docs/en/llm-gateway-protocol#system-prompt-attribution-block) that Claude Code puts first in the `system` array. To check, compare these fields in the request that the gateway received and in the one that it sent to the provider. Apart from `cache_control` markers, their content should be identical.
533* **Forward the rejection unchanged**: when the provider's status code and error body reach the session unchanged, the session removes the earlier thinking blocks and retries. The user sees only the reply. If your gateway rewrites the error, the user can see the error. Each later message in that conversation then fails the same way. To check, see the error-forwarding requirement in [Context window and compaction](#context-window-and-compaction).
534 
526535### MCP tool search
527536 
528537[MCP tool search](https://code.claude.com/docs/en/mcp#scale-with-mcp-tool-search) loads MCP tool schemas on demand instead of inlining every schema into the context window. It reduces context pressure when many MCP tools are configured (sessions that otherwise compact every turn or two).
from line 744
735744* **`400` with your gateway's own error text**: the gateway rejected the summary request itself, for example on a request-size or token limit of its own. Raise or remove that limit for these requests.
736745 
737746For `Prompt is too long` without `automatic compaction failed`, or your gateway's own request-too-large error shown in the session, check the `usage` and error-forwarding requirements in [Context window and compaction](#context-window-and-compaction) first. [Prompt is too long](https://code.claude.com/docs/en/errors#prompt-is-too-long) in the Claude Code error reference covers the other causes.
747 
748**Every message in one conversation fails, and new conversations work.** In the gateway's logs, find the provider's response to one of the failed requests. If its message says that a thinking block is `bound to a different conversation`, compare it with the response that your gateway returned for that request. If the status code or the error body differs, see [Gateway requirements for preserved thinking](#gateway-requirements-for-preserved-thinking). Once your gateway forwards the error unchanged, the user's next message in the same conversation goes through.
738749 
Feedback