Follow Discord
Sweep 02 Oct 2026 · 18:55Z Build v2.1.288 509 read Stable v2.1.285 Latest v2.1.288 Next v2.1.288 Feeds RSS JSON llms.txt llms-full.txt Unofficial
One change · claude-code

Interactive mode changedinteractive-mode

Nearest release: v2.1.288, published 12 hours after upstream edited the page. Shown because the two are within 24 hours of each other. Nothing here says the release caused the edit.

Upstream edited this page at 2 Oct 2026 06:08 UTC, give or take a minute or two: the time comes from Anthropic’s own sitemap rather than from a commit. This site recorded the change at 2 Oct 2026 06:37 UTC.

Upstream edited
Recorded here
Lines+9added
Lines−6removed
From line 649 where the diff opens
First seen 14 Aug 2026 this site's first read of the page
Recorded edits53to this page, all time

The whole hunk

from line 649, old and new numbered
/
lines
from line 649
649649 
650650When a claude.ai [usage limit](/docs/en/errors#youve-hit-your-session-limit) stops Claude mid-task, Claude Code waits in the open session and continues the task on its own after the limit resets. Automatic continue is on by default in interactive sessions signed in with a claude.ai subscription. Requires Claude Code v2.1.234 or later.
651651 
652While Claude Code waits, a line at the bottom of the session shows when it will continue:
652While Claude Code waits, the lines at the bottom of the session show when your limit resets and when Claude will continue:
653653 
654654```text theme={null}
655Usage limit reached · continuing automatically at 3:45pm · esc to cancel
655Usage limit reached · limit resets 3:45pm
656Continuing automatically at 3:45pm · esc to cancel
656657```
657658 
659Either line can carry more after these words, such as a help link on the first or `/usage-credits to continue now` on the second. When the wait starts on its own, the conversation also records it with a line that reads `Usage limit reached · continuing automatically at 3:45pm · esc to cancel`.
660 
658661Keep the session open. What happens next depends on how the wait ends:
659662 
660* **At the reset**: the line reads `continuing shortly`, then `Usage limit reset · continuing automatically`, and Claude Code sends Claude a fixed prompt to pick the task up where it stopped. It doesn't resend your last message.
661* **After your computer slept**: if it slept for more than about 30 minutes and the limit reset while it slept, the line reads `Your usage limit has reset · press enter to continue`. Press `Enter` to continue. After a shorter sleep, Claude Code continues on its own.
663* **At the reset**: the second line changes to `Continuing shortly · esc to cancel`. Then `Usage limit reset · continuing automatically` appears in the conversation, and Claude Code prompts Claude to pick the task up where it stopped. It doesn't resend your last message.
664* **After your computer slept**: if it slept for more than about 30 minutes and the limit reset while it slept, the first line reads `Your usage limit has reset` and the second reads `Press enter to continue`. Press `Enter` to continue. After a shorter sleep, or one that ended before the reset, Claude Code continues on its own.
662665* **Early**: when you finish adding [usage credits](/docs/en/costs#add-usage-credits-to-your-subscription) with `/usage-credits`, sign back in after `/upgrade`, or switch models with `/model` during the wait, Claude Code checks whether usage is available again and continues right away if it is. It doesn't check after an upgrade or purchase you make in a browser on your own. Under [`opusplan`](/docs/en/model-config#opusplan-model-setting) and other model settings that run plan mode on a different model, Claude Code waits for the reset instead.
663666 
664667The continued task runs like any other turn. Claude Code still asks for [permissions](/docs/en/permissions) as usual, so the task can stop on a prompt while you're away. If it hits the limit again, Claude Code re-arms the wait on its own at most twice in a row, then stops and shows `Automatic continue stopped after repeated usage-limit hits · /rate-limit-options to try again`.
from line 668
665668 
666669### Cancel the wait
667670 
668Press `Esc` at an empty prompt, or `Ctrl+C`, while the line shows, or run [`/rate-limit-options`](/docs/en/commands#all-commands) and pick **Don't continue automatically**. Claude Code confirms with a line that starts `Automatic continue cancelled`.
671Press `Esc` at an empty prompt, or `Ctrl+C`, while the lines show, or run [`/rate-limit-options`](/docs/en/commands#all-commands) and pick **Don't continue automatically**. Claude Code confirms with a line that starts `Automatic continue cancelled`.
669672 
670673After a cancel, nothing continues until you send a prompt or pick the row that starts **Wait here, then continue automatically** from `/rate-limit-options` again. Claude Code doesn't start a wait on its own again for that reset window; the next reset window starts fresh.
671674 
672675The wait also ends without continuing the task in these cases:
673676 
674* **You send a prompt**: Claude Code runs your prompt instead of waiting.
677* **You send a prompt**: Claude Code sends your prompt instead of waiting. If your prompt hits the limit too, it stays in the conversation and Claude Code starts the wait again.
675678* **You exit Claude Code**: the wait doesn't restart when you resume the session.
676679* **The conversation changes hands**: you switch accounts with `/login`, clear or rewind the conversation, `/resume` another session, pull one with `/teleport`, relaunch with `/tui`, or hand the session to Claude Desktop, a background session, or the cloud.
677680* **The setting turns off, or the reset moves past 24 hours**: this ends only a wait Claude Code started on its own. A wait you picked from `/rate-limit-options` keeps counting down.
Feedback