Follow Discord
Sweep 02 Oct 2026 · 18:55Z Build v2.1.288 509 read Stable v2.1.285 Latest v2.1.288 Next v2.1.288 Feeds RSS JSON llms.txt llms-full.txt Unofficial
One change · api

thinking changedbuild-with-claude/thinking

Nearest release: v2.1.287, published 4 hours before this site recorded the change. Shown because the two are within 24 hours of each other. Nothing here says the release caused the edit.

Recorded here
Lines+2added
Lines−2removed
From line 530 where the diff opens
First seen 14 Aug 2026 this site's first read of the page
Recorded edits18to this page, all time

The whole hunk

from line 530, old and new numbered
/
lines
from line 530
530530 In rare cases where you need access to full thinking output, [contact Anthropic sales](mailto:[email protected]).
531531</Note>
532532 
533To see the model's reasoning, read the `thinking` blocks rather than prompting for reasoning in the response text. On Claude Fable 5.1, Claude Opus 5.5, Claude Sonnet 5.5, and Claude Fable 5, a request that attempts to elicit the model's internal reasoning as part of the response text can be refused with `stop_details.category: "reasoning_extraction"`. See [Refusal categories](https://platform.claude.com/docs/en/build-with-claude/refusals-and-fallback#refusal-response) for the field reference and handling guidance.
533To see the model's reasoning, read the `thinking` blocks rather than prompting for reasoning in the response text. On Claude Fable 5.1, Claude Opus 5.5, Claude Opus 5, Claude Sonnet 5.5, and Claude Fable 5, a request that attempts to elicit the model's internal reasoning as part of the response text may be refused with `stop_details.category: "reasoning_extraction"`. See [Refusal categories](https://platform.claude.com/docs/en/build-with-claude/refusals-and-fallback#refusal-response) for the field reference and [Keep reasoning in thinking blocks](https://platform.claude.com/docs/en/build-with-claude/refusals-and-fallback#keep-reasoning-in-thinking-blocks) for what to ask for instead.
534534 
535535### Streaming thinking
536536 
from line 1070
10701070 
10711071The tradeoff is context usage: long conversations consume more context space on keep-all models, because retained thinking blocks count as input like any other conversation history (see [Thinking and the context window](https://platform.claude.com/docs/en/build-with-claude/thinking#thinking-and-the-context-window)). The behavior is automatic in both regimes. No code changes or beta headers are required, and you should keep passing complete, unmodified thinking blocks back as described in [Preserving thinking blocks](https://platform.claude.com/docs/en/build-with-claude/thinking#preserving-thinking-blocks). To override the default in either direction, use [thinking block clearing](https://platform.claude.com/docs/en/build-with-claude/context-editing#thinking-block-clearing).
10721072 
1073**Switching models mid-conversation.** Keep passing thinking blocks back unchanged when you switch models, for example after a [classifier refusal fallback](https://platform.claude.com/docs/en/build-with-claude/refusals-and-fallback). A thinking block is readable only by the model that produced it and certain other models, and the API ignores or drops the blocks the target model can't read. On Claude Fable 5.1 and Claude Mythos 5.1 the direction matters: they read every earlier model's thinking blocks and no earlier model reads theirs, so switching up to them keeps the conversation's reasoning and switching down drops it (see [how dropped blocks are billed and reported](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#switching-models)). Claude Opus 5.5 reads Claude Opus 5's thinking blocks and those of earlier Opus, Sonnet, and Haiku models, but not those of the Claude Fable and Claude Mythos models; on the Claude API, Claude Fable 5.1 and Claude Mythos 5.1 read Claude Opus 5.5's blocks. A switch from Claude Opus 5.5 up to Claude Fable 5.1 on the Claude API keeps the earlier turns' reasoning; a switch from Claude Fable 5.1 to Claude Opus 5.5 drops it. Claude Sonnet 5.5 reads thinking blocks from Claude Sonnet 5, Claude Opus 4.8, Claude Haiku 4.5, and earlier models, but not from Claude Opus 5, Claude Opus 5.5, or any Claude Fable or Claude Mythos model. On the Claude API, Claude Opus 5.5 reads Claude Sonnet 5.5's blocks and no other model does: a switch from Claude Sonnet 5.5 up to Claude Opus 5.5 on the Claude API keeps the earlier turns' reasoning, and any other switch away from Claude Sonnet 5.5 drops it. Strip prior `thinking` and `redacted_thinking` blocks yourself only to save input tokens on models that ignore rather than drop them, and never when redeeming a [fallback credit](https://platform.claude.com/docs/en/build-with-claude/fallback-credit), which requires the body unchanged.
1073**Switching models mid-conversation.** Keep passing thinking blocks back unchanged when you switch models, for example after a [classifier refusal fallback](https://platform.claude.com/docs/en/build-with-claude/refusals-and-fallback). A thinking block is readable only by the model that produced it and certain other models, and the API ignores or drops the blocks the target model can't read. On Claude Fable 5.1 and Claude Mythos 5.1 the direction matters: they read every earlier model's thinking blocks and no earlier model reads theirs, so switching up to them keeps the conversation's reasoning and switching down drops it (see [how dropped blocks are billed and reported](https://platform.claude.com/docs/en/build-with-claude/preserved-thinking#switching-models)). Claude Opus 5.5 reads Claude Opus 5's thinking blocks and those of earlier Opus, Sonnet, and Haiku models, but not those of the Claude Fable and Claude Mythos models; on the Claude API, Claude Fable 5.1 and Claude Mythos 5.1 read Claude Opus 5.5's blocks. A switch from Claude Opus 5.5 up to Claude Fable 5.1 on the Claude API keeps the earlier turns' reasoning; a switch from Claude Fable 5.1 to Claude Opus 5.5 drops it. Claude Sonnet 5.5 reads thinking blocks from Claude Sonnet 5, Claude Opus 4.8, Claude Haiku 4.5, and earlier models, but not from Claude Opus 5, Claude Opus 5.5, or any Claude Fable or Claude Mythos model. On the Claude API and Google Cloud, Claude Opus 5.5 reads Claude Sonnet 5.5's blocks and no other model does: a switch from Claude Sonnet 5.5 up to Claude Opus 5.5 on the Claude API and Google Cloud keeps the earlier turns' reasoning, and any other switch away from Claude Sonnet 5.5 drops it. Strip prior `thinking` and `redacted_thinking` blocks yourself only to save input tokens on models that ignore rather than drop them, and never when redeeming a [fallback credit](https://platform.claude.com/docs/en/build-with-claude/fallback-credit), which requires the body unchanged.
10741074 
10751075## Preserved thinking
10761076 
Feedback