Follow Discord
Sweep 08 Oct 2026 · 18:53Z Build v2.1.295 516 read Stable v2.1.286 Latest v2.1.295 Next v2.1.295 Feeds RSS JSON llms.txt llms-full.txt Unofficial
One change · claude-docs

Deploy Claude Desktop on 3P with an LLM gateway changedthird-party/claude-desktop/gateway

Nearest release: v2.1.285, published 2 hours before upstream edited the page. Shown because the two are within 24 hours of each other. Nothing here says the release caused the edit.

Upstream edited this page at 29 Sep 2026 19:50 UTC, give or take a minute or two: the time comes from Anthropic’s own sitemap rather than from a commit. This site recorded the change at 29 Sep 2026 20:07 UTC.

Upstream edited
Recorded here
Lines+1added
Lines−1removed
From line 181 where the diff opens
First seen 14 Aug 2026 this site's first read of the page
Recorded edits27to this page, all time

The whole hunk

from line 181, old and new numbered
/
lines
from line 181
181181 <Accordion title="inferenceStreamIdleTimeoutSec details">
182182 Raises how long Cowork, Chat and Code sessions wait for the next model event on an open streaming response (Claude Code's `CLAUDE_STREAM_IDLE_TIMEOUT_MS`). It only helps when the gateway writes SSE keep-alive `ping` events (or `:` comment lines) into the response while the upstream model is silent — for example a LiteLLM proxy with keep-alive pings enabled in front of Amazon Bedrock. With pings arriving, Claude Code accepts at least about five minutes of keep-alives and then waits this many seconds more for real model output before abandoning the request. Gateway provider only; the other providers keep Claude Code's defaults.
183183 
184 A response on which nothing at all arrives — no pings — still fails after about 5 minutes regardless of this key, because at the device a silent connection cannot be told apart from a dead one. If long generations fail behind a gateway that does not send pings, configure the gateway to send them rather than raising this value. While this key is set, the app's value takes precedence over `CLAUDE_STREAM_IDLE_TIMEOUT_MS` in Claude Code's own managed settings for sessions the app starts; when it is unset, that setting still applies. Values outside 300–1800 are rejected at parse time (the error is listed in the diagnostics report) and the default applies.
184 A response on which nothing at all arrives — no pings — still fails after about 5 minutes regardless of this key, because at the device a silent connection cannot be told apart from a dead one. If long generations fail behind a gateway that does not send pings, configure the gateway to send them rather than raising this value. A common case is automatic compaction, in which a session sends its whole conversation in one streaming request and waits for a long summary; when that request fails, the error reads `Prompt is too long · automatic compaction failed:` followed by the cause. While this key is set, the app's value takes precedence over `CLAUDE_STREAM_IDLE_TIMEOUT_MS` in Claude Code's own managed settings for sessions the app starts; when it is unset, that setting still applies. Values outside 300–1800 are rejected at parse time (the error is listed in the diagnostics report) and the default applies.
185185 </Accordion>
186186 
187187 <Accordion title="inferenceGatewayOidcAuthFlow details">
Feedback